Download document () of 20

Eaton 9PX split-phase UPS

Why choose an Eaton 9PX split-phase UPS? First of all, 9PX split-phase UPS models occupy less rack space than standard 9PX models and provide more room for your IT equipment while delivering better total cost of ownership. Without adding a bulky transformer or PowerPass distribution module, the 9PX split-phase power supply delivers a 120V or 208V output. Available in three models, from 6 to 10 kVA, the 9PX split-phase UPS allows you to attach battery modules for extended runtime.
Power rating
6–10 kVA
Output voltage
120/208V
Form factor
Rack/tower

Eaton 9PX split-phase UPS models

What are the advantages of a 9PX split-phase versus a traditional 9PX?

eaton_9px6sprack.jpg
  • Output: traditional 9PX UPS models (6–10 kVA) offer 208V only. On the other hand, 9PX split-phase UPS models natively offer both 120V and 208V output.
  • Rack space and weight: a 9PX UPS along with a transformer is heavier and occupies more rack space than the 9PX split-phase UPS. For example, the 9PX6KTF5 is 6U and weighs 91 kg (201 lb) while the split-phase 9PX6KSP is 4U and weighs 71 kg (157 lb).
  • Flexibilty: for flexible output connection options, you can easily pair split-phase models with a wide variety of PDU options.

Take a closer look at the 9PX split-phase UPS viewing both the front and rear panels

Interact now with:

9PX6KSP (5500 VA/4900 watts)

9PX8KSP (8 kVA/7200 watts)

9PX10KSP (10 kVA/9000 watts)

9pxsp-interactive.JPG

Reliable, versatile and efficient back-up power for IT equipment

Save time

Modular, transformerless design is designed for easy installation, reducing installation costs and time taken to deploy – providing both 120V and 208V circuits at the same time.
eaton_9pxsp-rear.jpg

Save space

The 9PX split-phase UPS has a compact footprint that does not require a transformer or power pass distribution module, which provides more space for IT equipment.
9PX8ksp.jpg

Reduce risk

Heightened cybersecurity with the optional UL 2900-1 compliant Gigabit Network Card improves business continuity by providing warnings of pending issues and helping to perform an orderly shutdown.
Eaton_NetworkCard-image.jpg

9PX split-phase UPS specification

Catalogue number Power rating (VA/watts) Input Output (120/208V output, 50/60 Hz) Dimensions (H x W x D, in.) Weight (lb.) Rack height
9PX6KSP 5,500/4,900 L14-30P (1) L14-30R, (1) L6-30R, (6) 5-20R, hardwired 6.8 x 17.3 x 29.77 157 4U
9PX8KSP 8,000/7,200 Hardwired (2) L14-30R, (1) L6-30R, hardwired 10.3 x 17.3 x 32.0 225 6U
9PX10KSP 10,000/9,200 Hardwired (2) L14-30R, (1) L6-30R, hardwired 10.3 x 17.3 x 32.0 225 6U

9PX split-phase extended battery module specifications

Catalogue number Description Compatible UPS model
9PXEBM240SP 6 kVA split-phase EBM (add up to four)
9PXS6KP
EBMCBL240SP 9PX EBM cable extension 6 kVA split-phase, 1.8 metres (6 feet) 9PXS6KP
9PXEBM360SP 8 and 10 kVA split-phase EBM (add up to four) 9PX8KSP, 9PX10KSP
EBMCBL360SP 9PX EBM cable extension, 8 and 10 kVA split-phase, 1.8 metres (6 feet) 9PX8KSP, 9PX10KSP