Download document () of 20

Reduce the risk of an arc flash in your business

For power-critical commercial and industrial buildings such as process plants, offices, hospitals and factories, a continuous supply of electrical power is essential.

The provision of reliable power in such buildings is reliant upon the low-voltage distribution switchboards that lie at the heart of the electrical installation. Demands placed upon these switchboards, particularly as operations and infrastructures expand over time, leave them vulnerable to arc flashes.

Despite these palpable dangers, electrical switchboards are easy to overlook in a safety analysis of commercial building infrastructure. The equipment is generally tucked out of sight and the prevailing view is that switchgear is absolutely safe as long as it conforms to the requirements of the IEC 61439 standard.

Research by independent experts suggests that compliance with the standard alone may not be sufficient to maximise protection; however, a higher level of safety can be achieved with the implementation of new technologies. As a result, it's possible to further reduce the risk of a catastrophic arc flash and its costly and potentially lethal aftermath.

Design tools for low-voltage electrical installations according to IEC standards

Designers of low-voltage power distribution solutions must consider many aspects when planning the correct electrical installation and selecting the correct devices. Eaton offers electrical consultants, electricians and power system engineers a variety of tools to help design the correct solution according to IEC standards.

Superior safety for maintenance personnel

Arc flash risk is greatest during maintenance operations. Eaton's new NZM digital circuit breakers can be equipped with Eaton's Arcflash Reduction Maintenance System (ARMS). ARMS' near-instantaneous reaction time greatly reduces arc flash energy and risk to personnel.

Arc flash protection video – safe solutions far beyond the IEC standards

Arc flashes can occur in electrical distribution systems, regardless of preliminary protective measures. See how an arc flash could cause potentially catastrophic damage to your people and your business.

Eaton offers a comprehensive range of solutions, such as DIAGNOSE and ARCON, to help businesses reduce the risk of costly plant shutdowns.

Bernhard Gegenbauer, Director Marketing and Products – Power Distribution Division – Eaton

Video outlining safety aspects to consider when installing low-voltage switchgear assemblies

 

In this video Alfred Mörx outlines the need to consider including a safety system within low-voltage electrical installations and how it can affect uptime and employee safety.

Customer success story

Airbus upgrades low-voltage switchgear using Eaton's support and expertise.