The Eaton 93PM UPS is the perfect three-phase white or gray space solution for modern data centers. The 93PM is compatible with lithium-ion UPS batteries, which are 40 percent smaller than VRLA batteries and have twice the lifespan, saving money on battery replacement costs and extra square footage for battery cabinets. The option of front-to-back or front-to-top ventilation maximizes deployment flexibility and lowers your cooling costs. In addition, you can add a number of optional, full integrated accessories for a complete system, including a maintenance bypass, a distribution cabinet (with input and output transformer options), a power distribution cabinet, parallel tie cabinets and battery cabinets as well as a wall-mounted or floor mounted bypass. Whether for a large data center, medical facility or educational institution, the efficiency provided by the 93PM can play a vital role in any low maintenance, ten-year power solution.
“It is by far the best investment that we have made. The 93PM and 9395 UPSs are saving us approximately $50,000 a year. We use it more as an insurance policy to ensure that our medical records stay up and running. An outage over a 24-hour period could easily be in the $300,000 range. We are a three million square foot hospital with 380 beds, so it would affect us quickly.”
10–400kW
480V, 415V, 400V, 380V, 220V, 208V
50/60 Hz
Double conversion with optional Energy Saver System (ESS)
Up to 97% in double conversion
Up to 99% in Energy Saver System
480V model: up to 8 internal power modules
208/220V model: up to 10 internal power modules
External parallel up to 8 UPSs
Tower
480V model: Internal batteries up to 50kW
415/400/380V model: Internal batteries up to 40kW
208/220V model: Internal batteries up to 60kW
External battery options for all models
10–200 kW in 5 kW increments at 208/220V
20–160 kW in 10 kW increments at 415/400/380V
20–200 kW in 10 kW increments at 480V
200–400 kW in 50 kW increments at 480V
Note: optional internal redundancy available for all models
Up to 99%
Up to 97%
Up to eight distributed. Some restrictions may apply; contact factory for more information.
Input characteristics | 480V models | 400V models | 208V models |
Voltage | 480/277V 4-wire 480V 3-wire |
380/220V 4-wire 400/230V 4-wire 415/240V 4-wire |
208/120V 4-wire 220/127V 4-wire |
Voltage range: | +10%/-15% | +10%/-10% | +15%/-15% @ 208V +10%/-15% @ 220V |
Frequency range | 50/60 Hz | 50/60 Hz |
50/60 Hz |
Power factor | > .99 | > .99 |
> .99 |
Input current distortion | < 3% @ 100% load capacity | < 3% @ 100% load capacity | ≤ 3.5% @ 100% load capacity |
Battery options | 480V models | 400V models | 208V models |
Battery voltage | 432V, 480V | 480V | 480V |
Charging method | ABM® or float technology | ABM® or float technology |
ABM® or float technology |
Battery type | VRLA, AGM, gel, wet, lithium, flywheel, super caps |
VRLA, AGM, gel, wet, lithium, flywheel, super caps |
VRLA, AGM, gel, wet, lithium |
Output | 480V models | 400V models | 208V models |
Voltage | 480 3-phase, 3-wire or 4-wire 208/120V with optional IAC-D, up to 200 kW |
380V, 400V or 415V 3-phase 3-wire or 4-wire |
208V or 220V 3-phase 3-wire or 4-wire |
Frequency range | 50/60 Hz | 50/60 Hz |
50/60 Hz |
Regulation | ±1% steady state | ±1% steady state |
±1% steady state |
Voltage THD | < 1% (100% linear load) < 5% (non-linear load) |
< 1% (100% linear load) < 5% (non-linear load) |
< 1% (100% linear load) < 5% (non-linear load) |
Load power factor range | Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating | Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating |
Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating |
Certification | 480V models | 400V models | 208V models |
Safety | UL 1778, cULus, UL 924 emergency, UL 924 auxiliary | UL 1778, cULus | UL 1778, cULus |
EMC | FCC Part 15 subpart B class A | FCC Part 15 subpart B class A |
FCC Part 15 subpart B class A |
Surge | IEC 61000-4-5 | IEC 61000-4-5 |
IEC 61000-4-5 |
Height: 74"
Depth: 42"
Width:
22”
32”
34.4"
43.3"
64"
The 93PM meets the strict standards for UL 924 compliance for emergency lighting applications when ordered with an emergency lighting SKU. For more information, visit Eaton.com/UL924UPS.
• Integrated maintenance bypass
• Integrated distribution cabinet (with input and output transformer options)
• Integrated power distribution cabinet
• Integrated parallel tie cabinets
• Integrated battery cabinet (small and large)
• Wall-mounted or floor-mounted bypass
• Lithium battery cabinet
• Custom options available. Contact factory for more information.