600VA 300W 120V Standby Cloud-Connected UPS with Remote Monitoring - 4 NEMA 5-15R Outlets (Surge + Battery Backup), 5-15P Plug, Desktop
Product Name |
Eaton Tripp Lite series standby UPS
|
Catalog Number |
BC600RNC
|
UPC |
037332283504
|
Product Length/Depth |
7.09 in
|
Product Height |
2.283 in
|
Product Width |
10.04 in
|
Product Weight |
4.41 lb
|
Compliances |
ENERGY STAR certified
FCC Class B RoHS |
Certifications |
CSA Std. C22.2
CSA certified ICES NOM UL 1778 |
Global Catalog |
BC600RNC
|
Battery Access |
Rear panel battery door
|
Battery Voltage (VDC) |
12
|
Battery Replacement Description |
Replaceable internal battery (see manual)
|
LED Indicators |
UPS- GREEN - ON SOLID when the line input voltage is normal and battery fully charged. FLASH GREEN in line mode when charging battery. FLASH GREEN every 10s when the UPS is supplying battery power to the loads. RED - Flashes when the battery needs to be recharged and tested. Cloud interface - Network Link/Activity (GREEN): Flashes when there is network activity. Network speed (Yellow): 100 Mbps network speed (On Solid), 10 Mbps network speed (Flashing).
|
Rechargeable Battery |
8 hours
|
Number of Outputs 5-15R |
4
|
Output waveform |
Sine wave
|
Voltage |
120V
|
Output nominal voltage |
120V
|
Nominal Output Voltage |
120V
|
Electric current - max |
|
Input connection |
5-15P
|
Input cord length |
5 ft
|
Input nominal voltage |
120 VAC
|
Nominal frequency |
50/60 Hz
|
Input frequency range |
50/60 Hz
|
Receptacle |
|
Input Circuit Breakers |
(1) 7A
|
Recommended Electrical Service |
15A 120V
|
Network Monitoring Port |
Network Configuration (options): with NFC; USB-C port: by enabling CLI commands.
|
Network Monitoring Port Description |
Ethernet port (RJ45) - Port connects to a local network.
|
Operating temperature - max |
122 °F
|
Operating temperature - min |
32 °F
|
Relative humidity |
0-95% RH @ 0-40C, non-condensing
|
Operating Temperature Range |
32° to 122°F (0° to 50°C)
|
Topology |
Standby
|
Form factor |
Desktop/Surface mount/Wall-mount
|
Wattage |
300W
|
Package contents |
|
Surge protection |
Yes
|
Application |
|
Audible Alarms |
In battery mode?Press and hold power button about 5 seconds?UPS will enter Temporary Mute?and then press and hold 5 seconds again to cancel this setting
|
Alarm Interface |
Audible Alarm Enable/Disable - In line mode?Press and hold power button about 10 seconds?Flashing Green LED indicates UPS will enter alarm Enable, Flashing Red LED indicates UPS will enter alarm Disable
|
Nominal Voltage Details |
120V
|
Runtime at half load |
5 min
|
Runtime at full load |
1.2 min. (300W)
|