Eaton Tripp Lite series metered outlet PDU, 3PH, 0U, IEC60309 input, 6ft cord, 23kW, 32A, 208-240V, 42 Outlets (36) C13 (6) C19, TAA
Product Name |
Eaton Tripp Lite series metered outlet PDU
|
Catalog Number |
PDU3XMV6G32
|
UPC |
037332182753
|
Product Length/Depth |
2.49 in
|
Product Height |
70 in
|
Product Width |
2.17 in
|
Product Weight |
14.29 lb
|
Compliances |
RoHS
CE Marked FCC Class A TAA Compliant |
Certifications |
IEC 62368-1
|
Form factor |
0U (Vertical)
|
Package contents |
|
Operating Temperature |
32° to 122°F (0° to 50°C)
|
Mounting direction |
Vertical
|
Material |
Metal
|
Input connection |
IEC-60309 32A RED (3P+N+E)
|
Cord length |
6 ft
|
Amperage Rating |
32A
|
Electric current - max |
32
|
Phase |
3-Phase
|
Frequency rating |
50/60 Hz
|
Number of Outputs C13 |
36
|
Number of Outputs C19 |
6
|
Features |
Flex Center
|
Front Panel LCD Display |
Large 3-digit display reports Amperage, Kilowatts, Voltage, Unbalance percentage; Small 2-character display verifies the measurement the large display is reporting: Input-phase (L#), Load bank (B#), Load unbalance (UB), Output power (OP)
|
Output Receptacles |
C13
C19 |
LED indicators |
Set of 6 LEDs verify the value displayed on the large 3-digit display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB); One additional LED for each output load bank (B1-B6) offers information power availability: GREEN (Power ON with <80% load), YELLOW (Power ON with >80% load), RED (Power OFF / undervoltage), RED FLASHING (Power OFF / breaker trip)
|
Overload protection |
Six 20A circuit breakers, 1 per outlet bank
|
Recommended electrical service |
Three-phase 32A 360-415V service
|
Reported load Segments |
Supports monitoring of input current per phase (L1, L2, L3) and output current for 6 separately breakered load banks (B1-B6); Outlets are color-coded and labeled for easy phase and load bank identification; L1-N feeds black outlets (B1, B4); L2-N feeds dark-gray outlets (B2, B5); L3-N feeds light-gray outlets (B3, B6)
|
Receptacles |
|
Input Cord Length |
6 ft
|
Switch configuration |
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power and Load balance options; Additional MODE button advances the LEDs to view available sub-options for each measurement category
|
Product Features |
TAA Compliant
|
Operating elevation |
0-10000 ft. (0-3000 m)
|
Operating temperature range |
32° to 122°F (0° to 50°C)
|
Output nominal voltage |
208-240V
|
Relative humidity |
5% to 95% non-condensing
|
Form Factors Supported |
Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
|
Output Capacity Details |
23kW (415/240V), 22.2kW (400/230V), 21.1kW (380/220V), 19.9kW (360/208V) total capacity; 32A max per output phase (L1, L2, L3); 20A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13 outlet
|
Storage temperature |
-22° to 140°F (-30° to 60°C)
|
Product Highlights |
0U Vertical Rackmount with Toolless button-mount installation
Local metered 22.2kW 3 Phase 360-415V input 208-240V output PDU TAA Compliant IEC309 32A Red (3P+N+E) 3 phase 360-415V input, 6-ft. (1.83 m) line cord Visual meter reports output amps per bank, total kW and input voltage 42 208-240V outlets (36 C13, 6 C19) with included plug-lock cord retention sleeves |
PDU Plug Type |
IEC-60309 32A RED (3P+N+E)
|
PDU Type |
Local metered
|
PDU Input Voltage |
360
|
PDU Form Factor |
Vertical (0U)
|
Support from Eaton