Eaton Green Motion Building is an AC electric vehicle charger designed for both indoor and outdoor use in private and public parking facilities for multi-residential, light commercial and industrial applications. This electric vehicle charging station provides multiple benefits:
Introducing Green Motion Building, an AC EV charger for multi-user settings and light commercial applications. Ideal for offices, retail, hospitality, sports and entertainment venues.
Have a closer look at the Green Motion Building EV Charger with Type 2 connector cable or socket options.
1 x 230 V 50 Hz – 1 phase
3 x 400 V 50 Hz – 3 phase
1 x 16 A (3.7 kW) – 1 phase
1 x 32 A (7.4 kW) – 1 phase
3 x 16 A (11 kW) – 3 phase
3 x 32 A (22 kW) – 3 phase
3.7 kW to 22 kW
Type 2 cable (Mode 3) or Socket (T2 or T2S)
Straight
1
–25 °C to +45 °C
Up to 2000 m
Wall-mounted, indoor or outdoor
< 95% relative humidity
Wall-mounted
Floor-mounted column (Optional)
285.5 x 264 x 116
3 kg
5 meters
IEC 61851-1
IP54
Built-in 6mA DC RDC-DD protection acc. to IEC62955
IK08
5 years
Multi-family homes (MFH) and parking facilities
LED strip status indicator
MID display
RFID
Eaton Charging network manager
Wi-Fi, Ethernet
Wi-Fi, Ethernet by default
LTE 4G (Optional)
OCPP 1.6J
Yes
Yes
Yes
Reference | Description |
GMB2202BCAA00A00 | GMB 3.7-22kW T2S MID 4GS |
GMB2201BBAA00A00 | GMB 3.7-22kW T2 Socket MID 4G |
GMB2203BAAA00A00 | GMB 3.7-22kW 5m T2C MID |
GMB2203BBAA00A00 | GMB 3.7-22kW 5m T2C MID 4G |
GMB2201BAAA00A00 | GMB 3.7-22kW T2 Socket MID |
GMB2202BAAA00A00 | GMB 3.7-22kW T2S MID |
GMB2202BBAA00A00 | GMB 3.7-22kW T2S MID 4G |
Reference | Description |
XCI3025221 | Cable holder |
XCI3025021 | Foot-mounted column for one charger |
XCI3025121 | Foot-mounted column for two chargers |
XCI000411 | RFID card x 5 |
GMA02AI000000A00 | N.1 ethernet extender kit |
GMA02AL000000A00 | N.2 ethernet extenders kit |
20 A breaker for the single-phase 16 A charging current | EMCH120 |
20 A breaker for the three-phase 16 A charging current | EMCH320, PLSM-C20/3N-MW |
40 A breaker for the single-phase 32 A charging current | EMCH140 |
40 A breaker for the three-phase 32 A charging current | EMCH340, PLSM-C40/3N-MW |
RCD type A for the single-phase 16 A charging current | PFIM-25/2/003-A-MW |
RCD type A for the single-phase 32 A charging current | PFIM-40/2/003-A-MW |
RCD type A for the three-phase 16 A charging current | PFIM-25/4/003-A-MW |
RCD type A for the three-phase 32 A charging current | PFIM-40/4/003-A-MW |
20 A RCBO (MCB+RCD Type A) for the three-phase 16 A charging current | MRB4-20/3N/C/003-A |
Mode 3 in accordance with EN/IEC 61851-1 AC charging
Type 2 cable: up to 32 A/400 V AC in accordance with EN/IEC 62196-1 and EN/IEC 62196-2
EN 61851-21-2, EN 61000-6-1, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12